You are here

Integrated EEG/NIR Sensor System for Infants

Award Information
Agency: Department of Health and Human Services
Branch: National Institutes of Health
Contract: 9R44MH100707-02
Agency Tracking Number: R44MH100707
Amount: $1,000,000.00
Phase: Phase II
Program: SBIR
Solicitation Topic Code: NIMH
Solicitation Number: PA11-096
Timeline
Solicitation Year: 2012
Award Year: 2012
Award Start Date (Proposal Award Date): N/A
Award End Date (Contract End Date): N/A
Small Business Information
500 E. 4th Ave Second Floor
EUGENE, OR -
United States
DUNS: 809845365
HUBZone Owned: No
Woman Owned: No
Socially and Economically Disadvantaged: No
Principal Investigator
 CATHERINE POULSEN
 (541) 687-7962
 cpoulsen@egi.com
Business Contact
 PUAL HOLMAN
Phone: (541) 687-7962
Email: pholman@egi.com
Research Institution
 Stub
Abstract

DESCRIPTION (provided by applicant): The goal of this SBIR project is to design a cost-effective, lightweight, integrated, whole-head dense-array electroencephalography and near-infrared spectroscopy (dEEG/NIRS) brain imaging and data analysis system for non-invasive recording of brain activity in neonates and young children. This system will permit bedside monitoring of immediate at-risk neonates, and early identification and intervention for abnormalities that predict developmental disabilities and cognitive deficits. A dense array of 128 combined optoelectrodes sitting on the surface of the scalp will simultaneously record brain electrical activity (EEG), and cerebral blood oxygenation changes (NIRS), providing complementary measures of brain function. Having demonstrated feasibility in Phase I with a partial array and single modulated wavelength, the first Specific Aim in Phase II is to extend the approach to complete a commercially viable, whole-head and dual-wavelength dEEG/NIRS acquisition system for infants. The existing design will be modified to use dual-wavelength LED emitters for hemoglobin measurements, with enhanced stability and robustness of the integrated optoelectrodes. New architecture will modulate up to 64 NIR light sources (32 dual-wavelength LEDs) at different frequencies and demodulate signals from up to 96 detectors. NIRS data acquisition software will be refined and further improvements will be made to the integration and synchronization with other acquisition streams, including Net Station EEG, Polygraphic Input Box data (e.g., ECG, EMG), and E-Prime experimental control software. The second Specific Aim is to design commercial, advanced data analysis tools for accurate computation of blood oxygenation changes measured with integrateddEEG/NIRS sensors. This NIRS analysis software will complement EGI's existing EEG processing and source analysis software. The first step will be to implement standard computational tools (based on the modified Beer-Lambert equation) that are used to determine changes in oxy- and deoxy-hemoglobin as measured by recovered NIR signals. Then, the computational parameters will be refined through advanced anatomical infant head modeling, and numerical modeling of the path, scattering, and absorption properties of NIR light through infant head tissues. The third Specific Aim will test and validate the integrated dEEG/NIRS system hardware and software for data integrity, functionality, and usability. Simultaneous dEEG and NIR data will be collected with the complete 128-sensor system during resting state and functional tasks in 30 neonates. The functional data task wil present simple speech and matched non-speech sounds that have previously resulted in individual differences in brain electrical patterns predictive of later dyslxia diagnosis. Outputs from in-house NIRS analysis tools will be cross validated with existing open-source analysis tools (e.g., HomER). Usability of the acquisition and analysis software will be assessed and further refinements made. Finally,commercial user guides for hardware, acquisition software, and analysis software will be prepared to accompany the dEEG/NIRS acquisition and analysis product. PUBLIC HEALTH RELEVANCE: The goal of this project is to develop the first lightweight device capable of providing real-time spatial and temporal brain imaging information regarding newborn and young infant neural functioning. Such a development would facilitate bedside monitoring of immediate at-risk newborns and offer us the incredible opportunity to identify in very young infants the structural and functional abnormalities that may contribute to later emerging developmental disabilities. Such early identification is vital to the development of early interventions that may mitigate or even preclude the emergence of the disorder.

* Information listed above is at the time of submission. *

US Flag An Official Website of the United States Government