Abstract:

Future NASA Space Science Missions will incorporate detectors, sensors, shields, and telescopes that must be cooled to cryogenic temperatures. An enabling technology for these missions is advanced cryocoolers that can provide continuous and distributed cooling with minimal input power. On this program, Creare proposes to develop and demonstrate an innovative cryocooler that produces refrigeration at temperatures of 30 to 70 K and rejects heat at a temperature of 150 to 210 K with extremely high efficiency. The heat rejected can be absorbed by an upper stage cryocooler or rejected to space through a small cryo-radiator. The overall mass of the cryocooler, cryo-radiator and electronics is nominally 6 kg, the area of the cryo-radiator is 0.8 m2 and the input power is significantly less than current state-of-the-art cryocoolers. The electronics utilize parts that are tolerant to 300 kRad total ionizing dose. In addition, the cryocooler technology is extremely reliable and scalable, and produces no perceptible vibration. The key innovation is a cryogenic compressor which has heritage to the cryogenic circulator developed by Creare and operated on the Hubble Space Telescope for 6.5 years. On the Phase I project, we optimized the cryocooler design for a particular mission class and predicted the performance of the cryocooler using a combination of analyses and component-level test data. On the Phase II project, we will build and test a demonstration cryocooler and cryo-radiator. The Phase II testing will be structured to achieve a TRL of at least 5, and will include cryogenic performance and launch vibration testing.

Principal Investigator:

Mark V. Zagarola
Principal Investigator
6036433800
mvz@creare.com

Business Contact:

James Barry
President
6036433800
contractsmgr@creare.com
Small Business Information at Submission:

Creare, Inc.
P.O. Box 71 Hanover, NH 03755-3116

EIN/Tax ID: 020259551
DUNS: N/A
Number of Employees:
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No